Key result
Photon-counting detector CT achieves ~96% sensitivity for detecting coronary in-stent restenosis.
Why the study?
Conventional CCTA after coronary stent implantation is limited by metal-related artifacts, while photon-counting detector CT (PCD-CT) offers improved spatial resolution, motivating a systematic evaluation of its diagnostic accuracy for detecting in-stent restenosis.
Does photon-counting detector CT coronary angiography accurately detect coronary in-stent restenosis of >=50% luminal diameter stenosis compared with invasive coronary angiography in patients with prior coronary stent implantation?
Systematic Review (n=511)
Yes
Does photon-counting detector CT coronary angiography accurately detect coronary in-stent restenosis of >=50% luminal diameter stenosis compared with invasive coronary angiography in patients with prior coronary stent implantation?
Photon-counting detector CT coronary angiography demonstrates high sensitivity (median 96.3%) and negative predictive value (91.7%-100.0%) with low non-evaluable stent rates (0.9%-6.8%) for ruling out >=50% coronary in-stent restenosis, though high risk of verification bias and low positive predictive value currently limit definitive clinical conclusions.
Answers are grounded in this paper and cite their sources.
May support noninvasive rule-out of in-stent restenosis; extends conventional CTA evidence but limited by bias and false positives.
Coronary computed tomography angiography (CCTA) following coronary stent implantation is limited by metal-related artifacts, whereas photon-counting detector computed tomography (PCD-CT) offers improved spatial resolution. This systematic review evaluated the diagnostic accuracy of PCD-CT angiography for detecting in-stent restenosis (ISR) of ?50% luminal diameter stenosis using invasive coronary angiography (ICA) as the reference standard and summarized in vivo evidence regarding coronary stent visualization. Five electronic databases were searched from inception. Two reviewers independently screened studies, extracted relevant data, and assessed the risk of bias using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. Findings were synthesized without meta-analysis in accordance with the Synthesis Without Meta-analysis (SWiM) reporting guideline, and the certainty of evidence was evaluated using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. Twelve studies involving 511 patients were included, comprising eight diagnostic accuracy studies and four stent visualization studies. Five diagnostic accuracy studies provided complete 2 × 2 contingency table data for 560 stents or lesions. Sensitivity ranged from 75.0% to 100.0% (median: 96.3%), specificity from 83.0% to 98.7% (median: 90.4%), and negative predictive value from 91.7% to 100.0%. Positive predictive value was below 63% in four studies. The proportion of nonevaluable stents or lesions ranged from 0.9% to 6.8%. Ultra-high-resolution reconstruction improved specificity in within-study comparisons; however, seven of the eight diagnostic accuracy studies were assessed as having a high risk of bias, primarily due to selective verification. PCD-CT coronary angiography may be useful for ruling out clinically significant coronary in-stent restenosis in selected clinical settings. However, false-positive findings and low to very low certainty of evidence limit definitive conclusions regarding its clinical utility. Further prospective diagnostic accuracy studies incorporating complete verification with invasive coronary angiography are warranted.
No takes yet. Share an insight, caveat, or question.
Rasyid et al. (2026) conducted a systematic review in Coronary in-stent restenosis (n=511). Photon-counting detector CT coronary angiography (PCD-CT) vs. Invasive coronary angiography (ICA) reference standard / Energy-integrating detector CT (EID-CT) was evaluated on Diagnostic accuracy (sensitivity and specificity) for detecting ≥50% in-stent restenosis at the stent or lesion level against invasive coronary angiography (Median sensitivity 96.3% (range 75.0%-100.0%); Median specificity 90.4% (range 83.0%-98.7%)). Photon-counting detector CT coronary angiography achieved 96.3% median sensitivity and 90.4% median specificity for detecting ≥50% coronary in-stent restenosis.