Key result
Intra-annular self-expanding TAVR linked to ~3.5-fold higher pacemaker placement versus supra-annular valves.
Why the study?
Intra-annular self-expanding valves are a relatively recent addition to transcatheter heart valves in the United States compared with supra-annular self-expanding valves, and evidence specifically comparing the two is sparse.
Does transcatheter aortic valve replacement with an intra-annular self-expanding valve affect midterm survival, permanent pacemaker placement, and paravalvular regurgitation compared to a supra-annular self-expanding valve in patients undergoing TAVR?
Observational (n=2,294)
No
Does transcatheter aortic valve replacement with an intra-annular self-expanding valve affect midterm survival, permanent pacemaker placement, and paravalvular regurgitation compared to a supra-annular self-expanding valve in patients undergoing TAVR?
In patients undergoing self-expanding TAVR, intra-annular valves were associated with comparable 2-year survival and 1-year paravalvular regurgitation rates compared to supra-annular valves, but had a significantly higher rate of new permanent pacemaker placement.
Answers are grounded in this paper and cite their sources.
Comparable safety between intra- and supra-annular designs may guide individualized TAVI selection; leaves open need for randomized trials to confirm findings.
BACKGROUND: Intra-annular self-expanding valves have been a relatively recent addition to transcatheter heart valves in the United States when compared with the more established supra-annular self-expanding valve. Although many studies have compared outcomes between self-expanding and balloon-expandable valves, evidence specifically comparing intra-annular and supra-annular self-expanding valves is sparse. METHODS: This is a retrospective observational study including all patients who underwent transcatheter aortic valve replacement with a self-expanding valve in our institutional TVT (Transcatheter Valve Therapy) registry between 2014 and 2024. Patients were grouped between the intra-annular and supra-annular groups. RESULTS: Of 5470 patients undergoing transcatheter aortic valve replacement in the time period, a total of 2294 patients underwent transcatheter aortic valve replacement with self-expanding valves, including 356 (18.4%) with intra-annular and 1938 (84.5%) with supra-annular. Propensity-score matching provided 354 patients in each group. After propensity-score matching, the incidence of new permanent pacemaker placement was higher in the intra-annular group (11.9% versus 3.4% in the supra-annular group, P<0.001). Moderate or greater paravalvular regurgitation was only seen in 1.6% (n=11) overall. Although mild paravalvular regurgitation was more frequently seen in the intra-annular group at the immediate postoperative echocardiogram (22.0% versus 11.9% in the supra-annular group, P<0.001), its statistical differences diminished at 1 year (5.1% in the intra-annular group versus 8.5% in the supra-annular group, P=0.07). The midterm survival was comparable between groups at 2 years. A Cox hazard analysis demonstrated that the type of valve was not associated with all-cause mortality (hazard ratio, 1.06 [95% CI, 0.72-1.57], P=0.77). CONCLUSIONS: Permanent pacemaker placement was significantly higher in the intra-annular group. This may be related to only high-risk approval for intra-annular valves. Survival and other complications were comparable between the groups.
No takes yet. Share an insight, caveat, or question.
Ogami et al. (2026) conducted an observational in Aortic valve disease requiring transcatheter aortic valve replacement (n=2,294). Intra-annular self-expanding transcatheter aortic valve vs. Supra-annular self-expanding transcatheter aortic valve was evaluated on New permanent pacemaker placement (p=<0.001). Intra-annular self-expanding TAVR had higher permanent pacemaker placement than supra-annular valves, with comparable all-cause mortality.
Synapse has enriched 10 related papers. Consider them for comparative context: