Why the study?
Recurrence after AF catheter ablation may reflect heterogeneity in atrial and systemic substrate burden, prompting evaluation of the temporal reproducibility, recurrence associations, and incremental prognostic value of outcome-independent multidomain pre-ablation phenotypes.
Population
1654 patients undergoing first-time AF ablation (1552 in the 3-month landmark cohort)
Comparison
Higher cardiometabolic-inflammatory phenotype vs lower systemic-burden phenotype derived from 17 pre-ablation variables
Design
Retrospective cohort study with unsupervised clustering
Follow-up
3 months and 12 months
Answers are grounded in this paper and cite their sources.
Substrate phenotypes may aid AF ablation recurrence risk stratification; leaves open prospective validation before clinical adoption.
Background: Recurrence after atrial fibrillation (AF) catheter ablation may reflect heterogeneity in atrial and systemic substrate burden. We investigated the temporal reproducibility of outcome-independent multidomain pre-ablation phenotypes, their associations with recurrence, and their incremental prognostic value. Methods: This retrospective cohort included 1654 patients undergoing first-time AF ablation. Partitioning around medoids clustering with domain-balanced Gower distance integrated 17 pre-ablation variables across six domains. Cox regression evaluated early recurrence within 3 months in the full cohort and post-blanking recurrence by 12 months and during follow-up in the 3-month landmark cohort (n = 1552). Stability, temporal reproducibility, continuous substrate-position associations, and incremental prediction were evaluated. Results: Clustering identified a lower systemic-burden phenotype (n = 772) and a higher cardiometabolic-inflammatory phenotype (n = 882). The latter had greater cardiometabolic and inflammatory-nutritional burden, larger left atrial diameter, and reduced renal function. It was associated with post-blanking recurrence by 12 months [adjusted hazard ratio (HR): 3.47, 95% confidence interval (CI): 2.54-4.75] and during follow-up (HR: 2.85, 95% CI: 2.28-3.56), but not significantly with early recurrence (HR: 1.19, 95% CI: 0.80-1.79). Internal temporal validation showed substantial agreement between frozen assignments and independently derived clusters (adjusted Rand index: 0.775; agreement: 94.0%). The continuous score was nonlinearly associated with recurrence. Adding phenotype membership to a clinical benchmark model increased the apparent time-dependent area under the receiver operating characteristic curve from 0.6941 to 0.7068, although incremental discrimination varied across out-of-bag bootstrap evaluations. Conclusions: Multidomain phenotyping identified pre-ablation profiles associated with post-blanking recurrence that demonstrated internal stability and temporal reproducibility.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: