Climate warming is raising cooling demand in U.S. school buildings, particularly in the hot and humid Southeast. This study quantifies how cooling energy use and the relative effectiveness of energy efficiency measures (EEMs) change in a representative primary school across a hot-humid climate gradient and over multi-decade horizons. The DOE Primary School prototype is simulated in EnergyPlus for Miami (1 A), Melbourne (2 A), and Atlanta (3 A), using a contemporary typical-year baseline and three RCP 8.5 scenario years (2020, 2040, 2060) generated in Meteonorm 8. Seven individual EEMs and one combined envelope-and-cool-roof package are evaluated across the three zones and four periods (12 zone-period combinations, 108 simulations), plus three integrated retrofit packages for contemporary and 2060 conditions (18 simulations). Baseline cooling electricity rises by roughly 22–38% by 2060, and its share of total site energy grows from 25 to 41% to 32–44%. Relative to baseline cooling electricity, HVAC efficiency upgrades (COP 3.2 → 4.0) give the largest and most stable single-measure savings (≈19% in every zone and period, because the model changes only the rated COP), followed by the combined package (16–19%). Infiltration reduction is the only measure that gains effectiveness over time, rising from 2.9% (Atlanta contemporary) to 7.2% (Miami 2060) as latent loads grow, while solar-driven measures decline. Spearman rank correlation shows priority rankings are highly stable in Atlanta (ρ = 0.952) and Miami (ρ = 0.976) but lowest in transitional Melbourne (ρ = 0.881). By 2060, Melbourne and Miami converge (ρ = 1.000) while Atlanta stays distinct. Separating a relatively more sensible-driven zone 3 A from zones 2 A and 1 A, which have higher latent-load fractions (sensible load remains the larger component in all three zones). On a total-site-energy basis, individual measures save at most 8.4% (9.2% for the combined package), and the rankings hold in Melbourne and Miami but change in Atlanta, where heating is more significant. Integrated passive-plus-HVAC packages save about 43% of cooling electricity and 19–22% of total site energy, less than the sum of their individual measures. HVAC efficiency and the envelope-and-cool-roof package lead in cooling-electricity terms in every zone and on an annual basis in Melbourne and Miami, whereas envelope measures lead on an annual basis in Atlanta; no single retrofit strategy is optimal everywhere, and mid-tier measures should be selected by zone.
No takes yet. Share an insight, caveat, or question.
Salih et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: