Pulmonary safety of inhaled colistin after lung transplantation remains uncertain. We retrospectively studied 507 lung transplant recipients transplanted between 2015 and 2026, evaluating treatment patterns, reasons for discontinuation, changes in forced expiratory volume in 1 s (FEV 1) after withdrawal, allograft biopsies, mortality, and chronic lung allograft dysfunction (CLAD). Inhaled colistin was administered to 203 recipients (40.0%), mainly for Pseudomonas aeruginosa (83.3%); 141 discontinued treatment after a median of 23.90 months. Suspected toxicity, poor tolerance, or functional deterioration was recorded in 31 recipients. Mean FEV 1 changes at 3 and 6 months after withdrawal were +30.45 mL (p = 0.140) and +4.07 mL (p = 0.855), whereas the best FEV 1 in the 6 months after withdrawal was 64.96 mL lower than before withdrawal (p = 0.008). Biopsies from six recipients showed eosinophilic intracellular inclusions in hyperplastic pneumocytes with mitochondrial-marker positivity. In time-dependent analyses, follow-up after colistin initiation was not associated with mortality (adjusted HR 1.207, 95% CI 0.842–1.731), but was associated with higher CLAD hazard (adjusted HR 1.823, 95% CI 1.276–2.604); landmark analyses did not reproduce this association. Withdrawal did not improve FEV 1, providing no signal of frequent clinically relevant reversible allograft dysfunction. The histopathological findings require validation, and the CLAD association should not be interpreted causally.