Answers are grounded in this paper and cite their sources.
Aiming at the difficulty of accurately characterizing the mapping between single-terminal fault transients and fault distance in HVDC transmission lines, this paper proposes a fault location method based on propagation-aligned interpolation augmentation and a time–frequency gated fusion network, combining the propagation-delay differences induced by distance variation with the time–frequency features of transients. To alleviate the insufficient distance coverage of training samples and the inconsistent wavefront arrival times caused by direct interpolation, adjacent waveforms with the same fault type and transition resistance are aligned and interpolated according to propagation delays calibrated on the training set, and an augmented training set is constructed together with end-zone densification and source quality screening. To promote time–frequency feature fusion, a dual-branch time–frequency gated fusion network is built, in which a CNN–BiLSTM branch and a Conv1D–SE branch extract transient temporal features and S-transform magnitude-spectrum features respectively, and feature-wise gated fusion then performs fault distance regression. Experimental results show that the proposed method achieves a mean absolute error of 0.285 km and a P95 error of 0.752 km, reducing the mean absolute error by about 48.6% compared with the equal-budget linear interpolation augmentation configuration. The proposed method helps improve single-terminal fault location accuracy under the experimental conditions of this paper.