Answers are grounded in this paper and cite their sources.
To improve the thermal performance of automotive prismatic lithium-ion battery modules, a multi-region conjugate heat transfer model comprising the cells, cold plate, and coolant was established in OpenFOAM. The equivalent single-cell model was assessed through a numerical consistency comparison with previously reported COMSOL-based results, and the computational grid was selected through mesh-independence and grid convergence index analyses. Coolant type, flow configuration, and inlet velocity were evaluated using an L9(33) orthogonal design under 2 C discharge. Range analysis and analysis of variance distinguished factor influence trends from statistical significance for the maximum module temperature, Tmax, and maximum temperature difference, ΔTmax. Among the nine cases, water with a six-inlet/five-outlet configuration and an inlet velocity of 0.0465 m/s yielded the lowest Tmax and ΔTmax, at 303.68 and 3.26 K, respectively. Coolant type significantly affected Tmax, whereas no factor was statistically significant for ΔTmax, although inlet velocity showed the largest variation trend. Seven supplementary computational fluid dynamics (CFD) cases formed a 16-sample dataset for a mixed categorical–continuous surrogate model coupled with NSGA-II. The equal-weight normalized ideal-distance criterion identified a compromise optimal scheme of 50% EG/H2O, six-inlet/five-outlet flow, and 0.0461 m/s; CFD recalculation yielded Tmax=304.71 K and ΔTmax=3.17 K.
No takes yet. Share an insight, caveat, or question.
Li et al. (2026) studied this question.