Answers are grounded in this paper and cite their sources.
Measuring wind direction in a marine environment requires high accuracy and robust performance under atmospheric conditions. Traditional potentiometric sensors suffer from premature wear and sliding contacts that degrade their performance. Magnetic encoders are contactless but may be susceptible to electromagnetic interference and magnet degradation. The latest-generation solutions based on ultrasonic technology often face limitations regarding cost, footprint, and precipitation sensitivity. This paper proposes a wind direction sensor based on an innovative stacked-coil inductive architecture, which combines multi-period accuracy within a 43 mm diameter footprint and potential for reduced costs. Static, semi-static, and dynamic tests were conducted in the laboratory using a motorized rotation stage and a wind tunnel. In the static tests, the sensor alone agrees with the reference stage within ±0.08° (including the stage’s own ≤ 0.05° accuracy), with a maximum standard deviation of 0.019° and a hysteresis up to 0.026°. Coupled to a commercial wind vane, the assembled prototype shows a mean error within approximately ±2° at wind speeds of 6 m/s and above, and an underdamped step response with a damping ratio between 0.25 and 0.32.
No takes yet. Share an insight, caveat, or question.
Foltran et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: