Pipes along slopes often run beneath shallow foundations. This numerical study examines how the burial depth and flexural stiffness of a buried PVC pipe govern its response beneath a strip footing on a sand slope. A PLAXIS 2D model validated against the footing response in nine reduced-scale model tests was used for 390 analyses covering slope angles of 20–35°, footing setbacks b/B = 0–1, burial depths H/D = 1–4 and pipe stiffness ratios EI/EI0 = 0.25–4. Pipe ovalization decreased six- to tenfold with depth and stiffness and increased with slope angle, while service wall stresses remained well below the design stress of PVC. Pipes buried shallower than about two footing widths reduced the bearing capacity, although the model underestimated this reduction relative to the tests. Gaussian process surrogates predicted the pipe response accurately (R2 ≥ 0.999) but the bearing capacity ratio (BCR) only moderately (R2 = 0.73, and 0.38 for unseen slope–setback combinations); a safety margin was therefore applied to the BCR constraint, and three of the resulting optimal designs satisfied it in independent finite element analyses. With only two design variables and a simplified relative cost index, GA, PSO and DE outperformed random sampling only for the constrained single-objective problem.