Purpose Standardized assessment of functional outcomes after hand surgery is lacking. Manual goniometry remains the clinical standard for hand range of motion assessment but is subject to interrater variability that complicates longitudinal monitoring. This proof-of-concept study evaluated two computer-vision-based motion capture systems: a single-camera smartphone application and a stereo depth-sensing camera, against manual goniometry performed by three independent human examiners, and assessed their potential to reduce interrater measurement variability. Methods Healthy volunteers (16 hands) underwent measurement of four hand motions (finger abduction, intermetacarpal distance, radial, and volar abduction) by two hand surgeons, one hand therapist, and the two computer vision systems. Primary outcomes were measurement agreement between the computer-vision systems and manual consensus (intraclass correlation coefficient [2,1], standard error of measurement) and measurement variability (coefficient of variation, CV%). Bland–Altman analysis assessed systematic bias and limits of agreement. Test-retest reliability was assessed in a subset of four hands at 1-hour intervals. Results Agreement between the computer vision systems and manual consensus was excellent to moderate (intraclass correlation coefficient range, 0.58–0.98). Both artificial intelligence systems demonstrated low intrasystem CV% compared with human interrater CV% across all motions. Mean bias was small, with 63% to 100% of measurements falling within predefined clinical agreement thresholds. Test-retest reliability was excellent to moderate for both systems (intraclass correlation coefficient range, 0.81–1.00), with standard error of measurement and minimal detectable change below clinical thresholds for most motions. Conclusions Both artificial intelligence systems demonstrated excellent to moderate measurement agreement with human consensus while maintaining low intrasystem measurement variability compared with human interrater variability across all four hand motions. Clinical relevance Smartphone-based computer-vision motion capture may offer a portable and accessible alternative to manual goniometry for standardized hand function assessment in clinical and remote monitoring settings.
No takes yet. Share an insight, caveat, or question.
Rydberg et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: