Answers are grounded in this paper and cite their sources.
The diamagnetic measurement system with a small integration time constant (RC=0.2 ms) was developed to detect weak diamagnetic signals on the NanChang Spherical Tokamak (NCST). The experimental results show that the plasma stored energy and energy confinement time can be measured using this system, with a residual flux error not exceeding 3.5×10⁻⁶ Wb and a preliminary estimate of τ E ≈ 4 ms. The diamagnetic measurement system developed in this work enables the plasma stored energy stored energy Wdia to be estimated from diamagnetic flux measurements during NCST discharges. Furthermore, the results can offer a valuable reference for diamagnetic signal measurements in other compact tokamaks.
No takes yet. Share an insight, caveat, or question.
Wu et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: