We consider four equiprobable dual-rail Bell states measured by a static passive interferometer with one ancillary photon. The $1/2$ success ceiling holds if that photon reaches at most three output modes, even with additional vacuum inputs. In five modes the three-output argument gives the sharper bound (1-(| AD|-| BD|)²)/2. A bound for arbitrary interferometers gives Psucc≤ 2/3, and gives Psucc≤1/2 when the two signal rail pairs have sufficiently little output overlap. A real three-port variant reproduces the exact $17/36$ success of an earlier Fourier circuit and gives an all-pattern determinant weight of $7/6$. The $1/2$ bound for arbitrary five-mode interferometers remains open in the literature checked here. Scripts, certificates and logs are in the attached zip and in the public repository https://github.com/yy5652-hash/open-research-notes-2026 (folder optics_bell_discrim). Produced with AI tools (OpenAI Codex for drafting and numerics, Claude Code for coordination and checking); each claim was checked by an independent second-model review and the accompanying scripts.
No takes yet. Share an insight, caveat, or question.
Yi Yu (2026) studied this question.