Answers are grounded in this paper and cite their sources.
We investigate the directed migration of weakly magnetic aqueous 4-hydroxy-TEMPO (TEMPOL) droplets immersed in diamagnetic phenylmethyl silicone oil. Gouy-balance measurements show an approximately linear concentration dependence of the dimensionless SI volume susceptibility of the solutions (R2=0.997). The fivefold-diluted solution has a measured susceptibility of −0.14×10−6 and a positive susceptibility contrast of 8.92×10−6 relative to the oil. Droplets of 1.0 and 2.0 µL traverse a 5mm interval toward the high-field region in 14.5 and 11.5s, respectively. An analytical permanent-magnet field coupled to a spherical Stokes model is evaluated against 32 concentration–volume combinations. All calculations use the same inputs: silicone-oil kinematic viscosity 30cSt, dynamic viscosity 30.4149mPas derived from the measured oil density, a fixed calculation height z=28mm, and drag coefficient κ=1. The mean absolute percentage error is 26.42%, the root-mean-square error is 6.466s, and the Pearson correlation coefficient is 0.818. Concentration and volume trends support susceptibility-contrast-driven migration, while systematic residuals identify the limits of the common fixed-height, constant-drag model. The results demonstrate magnetic transport of weakly magnetic liquid droplets without added solid magnetic particles.
No takes yet. Share an insight, caveat, or question.
Miao et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: