Answers are grounded in this paper and cite their sources.
Combined Cycle Power Plants (CCPPs) utilize Heat Recovery Steam Generators (HRSGs) to drive turbines for electricity generation. HRSGs are equipped with a sampling rack used to collect boiler water samples for laboratory analysis. The boiler water flowing to the sampling rack has a temperature exceeding 100-120 °C, and requires cooling to lower the water temperature. Before the WACOBLE innovation was implemented, cooling was carried out through a blowdown process by discharging a portion of the HRSG water, which potentially reduced water use efficiency. The former condition led to the implementation of the WACOBLE innovation which uses demineralized water as a coolant to lower the sample water temperature. This study aims to determine changes in water usage following the implementation of the WACOBLE innovation. The study employed a descriptive method based on annual water usage data, comparing the pre-innovation baseline in 2023 with the post-implementation state in 2024. The WACOBLE innovation utilizes demin water as a coolant to lower the boiler water temperature. The results show that annual water consumption decreased after the implementation of WACOBLE. Water consumption, which was previously 30,97 m³/year, decreased by 8,05 m³ to 22,92 m³/year, representing a 26% reduction. Based on these findings, the implementation of WACOBLE has proven effective in reducing regeneration water consumption and can serve as an innovation in efforts to improve water efficiency in HRSGs.