Answers are grounded in this paper and cite their sources.
A graphical procedure relates finite-length tie-beam section reductions to the measured and calculated narrow-cut response of one three-frame timber roof segment. Fifteen numerical cases combine reduction lengths of 100–300 mm with remaining heights of 20–60 mm. Local displacement and midspan deflection give separate equivalent cut-depth readings; an adopted common depth is then used to read approximate rotational stiffnesses k1 and k2 from the adjusted measured and calculated narrow-cut series, respectively. For a 200 mm long reduction with 40 mm remaining height, the local and midspan readings are 4.89 and 5.06 cm, with an adopted depth of 5.0 cm. Agreement with the narrow-cut curves and the subsequent spring-model response are assessed separately. Both displacements yield in-range depths for 12 of the 15 cases; three exceed the calculated response range. Experimental testing covered the narrow cuts.
No takes yet. Share an insight, caveat, or question.
Brodniansky et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: