PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 14, 2025Russian Journal of Cardiology0 citationsOpen Access

Comparative assessment of echocardiographic parameters, including the left ventricular global function index in patients with myocardial infarction with obstructive (MICAD) and non-obstructive coronary artery disease (MINOCA)

НМН. И. МаксимовIGI. S. GrishinNGN. S. Grishina

Key Result

Patients with MINOCA had better left ventricular geometry parameters on the first day of myocardial infarction compared to patients with MICAD, due to lower end-systolic dimension, EDV, and ESV.

Study Design

Type

Observational (n=170)

Multicenter

No

Structured PICO

How do echocardiographic parameters, including LV global function index, differ between patients with MINOCA and MICAD on the first day of myocardial infarction?

P
Population
170 patients hospitalized with myocardial infarction, divided into MINOCA (n=73) and MICAD (n=97) groups.
O
Outcome
Main parameters of transthoracic echocardiography, including left ventricular global function index (LVGFI) and LV geometry on the first day of the disease.surrogate

Echocardiographic parameters, particularly LV geometry and global function index, differ significantly between MINOCA and MICAD patients on the first day of myocardial infarction.

Abstract

Aim. To assess the main parameters of transthoracic echocardiography, including the global function index in patients with myocardial infarction with obstructive (MICAD) and non-obstructive coronary artery disease (MINOCA). Material and methods . The study included 170 patients with a diagnosis of myocardial infarction were hospitalized and underwent inpatient treatment at the Cardiology Department № 1 of the Republican Clinical and Diagnostic Center, Izhevsk. Coronary angiography was performed on a Phillips Allure Clarity system. Based on the procedure results, the patients were divided into 2 following groups: 1 — MINOCA (n=73); 2 — MICAD (n=97), who underwent stenting. Echocardiography was performed using a Siemens Acuson CV70 (Germany) for all patients on the first day of the disease (before coronary angiography). The main parameters of the left ventricle (LV) geometry were assessed. LV ejection fraction (EF) was determined using the Simpson method. The LV global function index (LVGFI) was determined using the following formula: LVGFI=stroke volume/ ((LV end-diastolic volume (EDV) + LV end-systolic volume (ESV))/2 + LV volume) × 100%. Based on the echocardiography data, the patients were divided into 2 following subgroups: 1 — low GFI (31,2%). Results . No differences in age were found. In the MINOCA group, there were more females — 57,6% vs 29,9%. Patients with MICAD more often had ST elevation and pathological Q wave — 70% vs 33%. Anterior wall MI was equally common. Patients with MICAD had a larger left atrium diameter and EDV. No differences were found in other echocardiographic parameters. EF was higher in patients in the MINOCA group (trend towards differences). Patients with low GFI in the MINOCA group are older, has a larger left atrium diameter, right atrium, end diastolic dimension, EDV, ESV, LV mass, and a higher rate of LV hypertrophy (40% vs 12,5%, p=0,008). LVEF in the low GFI MINOCA group was 55% (vs 64,9% in MICAD, p=0,004). In both subgroups, patients had the same frequency of ST elevation and pathological Q wave. Patients with low GFI, obstructive coronary artery disease and male sex more often had ST elevation and pathological Q wave. Conclusion . In patients with MINOCA, LV geometry parameters on the first day of the disease are better than in patients with MICAD due to lower values of the end-systolic dimension, EDV, ESV. Patients with low GFI had higher values of the end-diastolic dimension, EDV, ESV, LV mass, and more often had LV hypertrophy, lower EF. Patients with low GFI in the MICAD group compared to low GFI in MINOCA showed differences in sex (more often men), ST elevation rate, pathological Q wave, and a higher EDV.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Максимов et al. (2025) conducted an observational in Myocardial infarction with obstructive (MICAD) and non-obstructive coronary artery disease (MINOCA) (n=170). MINOCA vs. MICAD was evaluated on Main parameters of transthoracic echocardiography, including left ventricular global function index. Patients with MINOCA had better left ventricular geometry parameters on the first day of myocardial infarction compared to patients with MICAD, due to lower end-systolic dimension, EDV, and ESV.

synapsesocial.com/papers/6a0f87c328c2d29469fe1cf6https://doi.org/10.15829/1560-4071-2025-5852
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Comparative analysis of prothrombotic activity in patients with myocardial infarction with and without obstructive coronary artery disease2021 · 5 citations
  2. 2Systematic Review of Patients Presenting With Suspected Myocardial Infarction and Nonobstructive Coronary Arteries2015 · 992 citations
  3. 3CARDIAC MAGNETIC RESONANCE IMAGING IN DIFFERENTIAL DIAGNOSTICS OF ACUTE CORONARY SYNDROME IN PATIENTS WITH NON-OBSTRUCTION CORONARY ATHEROSCLEROSIS2017 · 8 citations
  4. 4Left ventricular global function index as a predictor of adverse cardiovascular events in patients with acute coronary syndrome2021 · 12 citations
  5. 5Left ventricular global function index: diagnostic and prognostic value in cardiovascular diseases2023 · 3 citations