January 6, 2015EP Europace75 citationsOpen Access

Incidence and characteristics of phrenic nerve palsy following pulmonary vein isolation with the second-generation as compared with the first-generation cryoballoon in 360 consecutive patients

View Full Paper
AFAlexander FürnkranzSBStefano BordignonBSBoris Schmidt

Key Result

The second-generation cryoballoon for pulmonary vein isolation resulted in a 2.8% rate of persistent phrenic nerve palsy compared to 1.9% with the first-generation balloon (P=0.63).

Study Design

Type

Observational (n=360)

Structured PICO

Does the second-generation cryoballoon alter the incidence and characteristics of phrenic nerve palsy compared to the first-generation cryoballoon in patients undergoing pulmonary vein isolation for atrial fibrillation?

P
Population
360 consecutive patients with atrial fibrillation undergoing pulmonary vein isolation
I
Intervention
Second-generation cryoballoon (CB2) for pulmonary vein isolation
C
Comparator
First-generation cryoballoon (CB1) for pulmonary vein isolation
O
Outcome
Incidence and characteristics of phrenic nerve palsy (PNP) (persistent and transient)safety

While the incidence of phrenic nerve palsy is similar between first- and second-generation cryoballoons, the second-generation device is associated with a significantly longer time to nerve function recovery.

Main Result

Absolute Event Rate: 2.8% vs 1.9%

p-value: p=0.63

Abstract

AIMS: The second-generation cryoballoon (CB2) with increased surface cooling has recently become available. The aim was to investigate the incidence and characteristics of phrenic nerve palsy (PNP) during pulmonary vein isolation (PVI) using the CB2 as compared with the first-generation balloon (CB1). METHODS AND RESULTS: A total of 360 consecutive patients with atrial fibrillation underwent PVI with the CB1 (106 patients) or the CB2 (254 patients). Right PN function was monitored by continuous stimulation and palpation during septal PV ablation. Persistent PNP (present at discharge) occurred in 2.8 and 1.9% (P = 0.63) of patients, transient PNP (full recovery before discharge) in 5.9 and 3.8% (P = 0.41) of patients in the CB2 and CB1 group, respectively. Phrenic nerve palsy during ablation at the right inferior PV was observed in 0% (CB1) and 4.3% (CB2, P = 0.03) of patients. Using the CB2, a trend of reduced incidence of persistent PNP over quartiles of consecutive patients was observed 4.8% (Q1) vs. 0% (Q4); P = 0.077. At the culprit PV, PNP occurred after 3.5 ± 2.1 (CB1) and 1.1 ± 0.4 applications (CB2; P = 0.036). Complete recovery of PN function occurred after 29 ± 11 (CB1) and 259 ± 137 days (CB2; P = 0.004). CONCLUSIONS: The rate of transient/persistent PNP associated with the use of the CB2 was 5.9 and 2.8%, respectively. Time to restitution of PN function was longer using the CB2.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Fürnkranz et al. (2015) conducted an observational in Atrial fibrillation (n=360). Second-generation cryoballoon (CB2) vs. First-generation cryoballoon (CB1) was evaluated on Persistent phrenic nerve palsy (present at discharge) (p=0.63). The second-generation cryoballoon for pulmonary vein isolation resulted in a 2.8% rate of persistent phrenic nerve palsy compared to 1.9% with the first-generation balloon (P=0.63).

synapsesocial.com/papers/6a1ca55f6552df3dce1d7ee9https://doi.org/10.1093/europace/euu320
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation: feasibility, complications, and short-term outcome2007 · 299 citations
  2. 2Left phrenic nerve injury after cryoballoon ablation of the pulmonary veins2012 · 16 citations
  3. 3Improved 1‐Year Clinical Success Rate of Pulmonary Vein Isolation with the Second‐Generation Cryoballoon in Patients with Paroxysmal Atrial Fibrillation2014 · 177 citations
  4. 4Second-generation cryoballoon ablation for paroxysmal atrial fibrillation: 1-year follow-up2014 · 155 citations
  5. 5Improved Procedural Efficacy of Pulmonary Vein Isolation Using the Novel Second‐Generation Cryoballoon2012 · 192 citations