Systematic approach evaluates calibration methods for reference cells measuring solar irradiance, indicating low-cost viability for photovoltaic applications.
Introduction: The procedures and calibration method of the reference cells can be performed by measurements on a solar simulator (indoor) or under natural light (outdoor). This study describes the development and indoor and outdoor characterization of reference cells used to measure solar irradiation. The reference cells were developed based on the lamination process used to encapsulate the photovoltaic cells. In tests with a solar simulator, the I-V curves, correlations of fill factors and short-circuit current were recorded for the reference cells. The cells presented a fill factor close to 70%. Outdoor calibration was performed using a standard cell (calibrated) and a thermoelectric pyranometer (calibrated). The measures were validated based on a photovoltaic pyranometer of a meteorological station located at the Federal University of Santa Catarina, UFSC, Brazil. The irradiances were measured at all seasons of the year and on sunny days (clear skies). The irradiance values measured were determined using the three calibration methods of the reference cells and showed a strong correlation with the irradiance of the photovoltaic pyranometer at the meteorological station. Within the sphere of work the impact of the different calibration methods on the measurement of solar radiation was examined through the development of a systematic approach to the statistical analysis of uncertainties. The cells obtained a coefficient of variation of approximately 2.5% based on the three calibration methods. Comparing each photovoltaic cell technology to a specific calibration method, the coefficient of variation was between 0.9% and 2.0%. Objective: This study aimed to develop and characterize low-cost reference cells for solar irradiance measurement, evaluating different calibration methods (indoor and outdoor) and their respective uncertainties. Theoretical Framework: The research is based on the premise that accurate solar irradiance measurement is essential for the sizing and operation of photovoltaic systems. However, the high cost of conventional equipment limits its widespread adoption. Reference cells are a viable alternative, provided their uncertainties are known and controlled. Method: Six reference cell prototypes were assembled using mono- and multicrystalline silicon technologies. The cells were laminated and electrically characterized under a solar simulator (indoor) and under natural sunlight (outdoor), using a calibrated reference cell and a thermoelectric pyranometer. Measurements were conducted throughout all seasons. Statistical analysis included standard deviation, root mean square deviation, and coefficient of variation (CV). Results and Discussion: The correlation coefficients (R²) between the measurements from the reference cells and the reference pyranometer exceeded 0.97. The average CV ranged from 0.9% to 2.5% across the different calibration methods and technologies, indicating good repeatability and precision. The indoor method, despite not using natural sunlight, showed performance comparable to the outdoor method. Research implications: The study validates the use of low-cost reference cells as reliable instruments for solar irradiance measurement, with potential application in small- and medium-scale photovoltaic plants. Originality/Value: The proposed approach is innovative in combining simple laboratory construction, comparative calibration, and systematic uncertainty analysis, offering accessible alternatives for solar monitoring.
No takes yet. Share an insight, caveat, or question.
Rosso et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: