Answers are grounded in this paper and cite their sources.
CFD and PBM approaches enhance bubble dynamics in venturi aerators, indicating a 766% increase in bubble density with air swirl.
The present study delves into the intricacies of bubble dynamics within a venturi aerator system, employing a combined computational fluid dynamics (CFD) and Population Balance Model (PBM) approach to optimize the generation and handling of air microbubbles. The investigation focuses on the role of swirling flows, introduced at varying air inlet velocities, and their influence on bubble size distribution and breakup within the venturi system. The Eulerian two-fluid model alongside the PBM is applied, and the k–ω Shear Stress Transport (SST) model is integrated to capture the turbulent flow characteristics effectively. The results demonstrate significant enhancements in bubble distribution uniformity and size reduction when swirl is implemented, especially at higher air velocities. Numerical simulations are validated against experimental data, ensuring the reliability of the predictions. The study found that the number density of bubbles at the outlet section is influenced by factors such as air stream velocity, use of swirl at the inlet, and the range of bubble diameters. Elevating the air stream inlet velocity from 1 to 10 m/s resulted in a 520 and 766% increase in the number density of the largest bubbles, and a 118 and 32% increase for the smallest bubbles, for cases without and with inlet swirl respectively.
No takes yet. Share an insight, caveat, or question.
Roohi et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: