Answers are grounded in this paper and cite their sources.
CFD simulation shows venturi with double inclined ribs improves microbubble production, indicating performance enhancement.
This study compared the analysis of a venturi with discrete double inclined ribs V-type added to the throat with a plain venturi. The analysis was conducted in the Reynolds number range of 8900 - 24000 by conducting CFD simulation of 1-phase flow by observing variations in the distance between ribs of 5 mm, 7.5 mm, and 10 mm, as well as variations in the venturi divergent angle of 7.5°, 10°, and 12.5°. The results of the one phase flow observation show the smallest variation of the distance between ribs, 5 mm and the largest variation of the divergent angle, 12.5°, which causes an earlier deceleration, which causes the bubble breakup process to occur earlier. Therefore, a two phase flow simulation with the Population Balance Model(PBM) model was conducted using ambient air, comparing the results of microbubble characteristics. As a result, the venturi with added ribs produces more microbubbles than the plain venturi, which is about 1 billion particles per unit volume, with the most particle size being 0.8 mm.
No takes yet. Share an insight, caveat, or question.
Amelia et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: