Answers are grounded in this paper and cite their sources.
Observational analysis revealed enhanced corrosion resistance of Ti–Zr–Nb–Ta alloy in Ringer solution, suggesting ARB processing improves stability for biomedical applications.
The potentiodynamic polarization behavior of as-cast and accumulative roll-bonded (ARB) Ti–10Zr–5Nb–5Ta alloys was investigated in neutral Ringer solution at 37 °C to assess the influence of microstructural refinement on corrosion resistance and passivation. Using the Tafel equation, the potentiodynamic behavior of the as-cast and ARB-processed alloys was modeled to quantify electrochemical performance, with results indicating that ARB processing significantly modifies passive film characteristics. Model predictions were compared with experimental data, showing good agreement. The models were then coupled with Monte Carlo simulation to account for uncertainties in experimental data and fitting parameters, enabling probabilistic predictions of corrosion behavior. This integrated approach provides a robust evaluation of variability and reliability in electrochemical performance, offering a comprehensive assessment of the alloy’s stability in physiological environments. The findings demonstrate that ARB processing can enhance corrosion resistance, supporting its potential for the development of durable titanium-based biomaterials for demanding biomedical and dental applications.
No takes yet. Share an insight, caveat, or question.
Alashti et al. (2025) studied this question.