An experimental and numerical study has investigated the heat transfer (HT) and friction characteristics of a solar air heater (SAH) duct roughened using a rectangular S‐shaped artificial roughness arrangement (inline and staggered). The thermal performance of SAH is studied with design variables such as the length of the relative roughness ( d/H = 1.33), the height of the relative roughness ( e/H = 0.271), and the distance between S ( b / H = 0.667) remaining constant as the Reynolds number ( Re ) ranges from 3000 to 10,000 and the angle of attack 60°. Relative roughness of pitch range p/H (1.667, 3.33, 5, and 6.667) for inline with relative roughness of length ( l/H ) (0.8335, 1.666, 2.5, and 3.335) for staggered. A three‐dimensional computational fluid dynamics (CFD) simulation is carried out using the CFD code, ANSYS Fluent, and the renormalization group k – ε turbulence model for solving turbulence terms in governing equations. It has been found that HT enhancement can be achieved by using an artificial roughness staggered arrangement at l/H = 0.8335 and e/D = 0.271 with an angle of attack ( α ) of 60°. Also offers the best thermal performance factor for the investigated range of 3.12.