Answers are grounded in this paper and cite their sources.
Analysis identifies key equipment failures and their impact on primary barrier envelope in drilling operations, suggesting improvements.
Managed Pressure Drilling (MPD) technique has been used in high complexity deep-water offshore wells off the Brazilian coast since 2011. The initial objective was to enable drilling of these wells that were undrillable conventionally. Nowadays, the use of the technique has been expanded, not only to enable, but also to optimize drilling in challenging scenarios. Despite MPD benefits, MPD application is still not developed to its full potential, since it is limited due to its own reliability issues. As part of the primary barrier envelope, some failure of equipment or control system can lead to an influx when using underbalanced fluid. Thus, beyond MPD equipment failures, it is necessary to understand which of them has the potential to degrade the first barrier envelope, and which failures have contingency barriers. This paper uses the MPD system failure historical data from over 100 drilled wells to share data on the major contributors to primary CSB integrity failures. It also analyses which systems or equipment should receive close attention in MPD operations.
No takes yet. Share an insight, caveat, or question.
Sales et al. (2025) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: