This analysis demonstrates a novel angle sensor that improves measurement precision through angle amplification using double-layer prisms, emphasizing multiple reflections and displacement measurements.
In this paper, a high-precision sensor for angle measurement with angle amplification based on the double-layer regular prisms structure was designed. The angle amplification was achieved by multiple reflections of the measurement laser between the inner and outer double-layer regular prism structure. The trajectory of the measurement laser within the double-layer regular prism structure was investigated, and a corresponding mathematical model was developed. A position-sensitive detector (PSD) measures displacement variations in the measurement laser and ultimately enables angle measurement by applying the displacement-to-angle conversion relationship derived from analysis of the reflection trajectory model. The sensor prototype achieved a measurement precision of ±0.5″. Additionally, the feasibility of the alternative measurement method using multiple measurement units was experimentally verified, while its measurement accuracy remained comparable to that of a single unit. The 360° angle measurement through proper arrangement of multiple PSDs can be achieved as well, and its feasibility has been discussed.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: