Optimized C-port structure improves fluid flow and cavitation reduction in hydraulic systems, indicating significant performance gains.
The pump-controlled asymmetric hydraulic cylinder provides primary power for the electro-hydrostatic actuator (EHA). The asymmetric pump compensates for the differential flow requirements of the hydraulic cylinder, and increasing the pump speed limit enhances the power density of the EHA. However, the non-dead-center transition zone in the asymmetric pump disrupts suction and discharge, limiting fluid exchange through the third port (C-port) and restricting speed improvements. This study presents an optimized C-port offset design (COD) to improve the fluid flow characteristics, reduce cavitation, and mitigate pressure surges in the piston chamber. The design enhances the suction and discharge performance of the C-port. A simulation model developed using the advanced modeling environment for simulation is employed to analyze pressure and flow characteristics within the piston chamber, with the results validated through experimental testing on a dedicated test rig. The findings show that the COD structure expands the flow area of the C-port to 8.64 mm2, a 184% increase compared to the conventional design. This improvement significantly enhances oil suction. Under clockwise rotation, the maximum speed in the high-efficiency range (volumetric efficiency above 90%) increases from 3700 to 5450 r/min, achieving a 47.3% improvement.
No takes yet. Share an insight, caveat, or question.
Ji et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: