Answers are grounded in this paper and cite their sources.
Observational analysis highlights Legionella contamination in water sources, indicating potential health risks.
The results of examining the water of its centralized supply sources were analyzed in the Sverdlovsk Region over 2009. Legionella DNA contamination was found to occur in 12.71±1.02% of the water samples, including that in 9.09±5.00 and 13.27±1.07% of the cold and hot water ones. Legionella DNA is most frequently detectable in the water in May-June and November-December. The isolation of Legionella cultures also demonstrates similar trends. The pattern of Legionella isolated in the Sverdlovsk Region showed a preponderance of L. pneumophila serogroups 2-14 (91.3%) detectable in a quantity of 10 (23.82%) to 1000 (38.09%) CFU/l in the hot water practically in the whole year. It was established there was a weak correlation between the incidence of community-acquired pneumonias and acute respiratory diseases and the detection rate for Legionella DNA (r = 0.15; p > 0.05). At the same time, such a correlation of moderate strength does not rule out the implication of Legionella in the etiology of nosocomial pneumonias (r = 0.61; p < 0.05).
No takes yet. Share an insight, caveat, or question.
Smirnova et al. (2011) studied this question.