Pilot project tested a damping system for reducing vortex-induced vibrations in davit arms, suggesting improved constructability.
Unloaded davit arms are subject to vortex-induced vibrations (VIV) and are required to be secured during installation. Traditional methods, such as hanging weights or using cable tie-downs have shown limitations, including increased dynamic stress and the necessity for periodic re-tensioning. To enhance constructability, AEP transmission has partnered with PLP to develop a lightweight, engineered davit arm damper. This innovative system minimizes interference with construction activities and meets energy dissipation requirements. A pilot project involving eight steel pole structures on a 345 kV line in Texas was conducted, comparing the performance of arms equipped with the damper, weights, tie-downs, and those without mitigation devices. Field monitoring over 9 months demonstrated the damper's effectiveness in reducing VIV. This paper provides detailed insights into the design, testing, and monitoring results.