Analysis improves feed utilization and spreading performance in aquaculture feeders, suggesting effective designs.
As a key device for precise feeding in aquaculture, feeders directly affect feed utilization efficiency and farming profitability; however, pneumatic pond feeders commonly exhibit poor spreading uniformity and low feed utilization. In this study, a dual-sided air intake structure incorporating a triangular flow-splitter plate was added inside the feed chamber, and the spreading process was simulated using a coupled computational fluid dynamics–discrete element method approach to analyze the motion mechanisms of feed pellets within the feeding device. A rotatable orthogonal composite experimental design was employed for the multiparameter collaborative optimization of the feed chamber height (h), the triangular flow-splitter plate width (d), and its inlet angle (α). The results demonstrated that the triangular flow-splitter plate renders the velocity field within the device chamber more uniform and reduces the coefficient of variation (CV) of circumferential pellet distribution to 18.27%, a 22.19% decrease relative to the unmodified design. Experimental validation using the optimal parameter combination confirmed a mean CV of 17.02%, representing a 24.45% reduction compared with the original structure. This study provides a theoretical foundation and reliable technical solution for precise feeding equipment in aquaculture.
No takes yet. Share an insight, caveat, or question.
Zhu et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: