This novel inverter design reduces leakage current and switch count in PV systems, suggesting improved efficiency and simplicity.
This paper presents a novel transformerless, common‐grounded, grid‐connected inverter for photovoltaic (PV) systems. The proposed architecture integrates a single‐switch bipolar boost converter in the direct current (DC)–DC stage and a half‐bridge inverter for the DC–alternating current (AC) conversion. The main features include the use of a single active switch in the DC–DC stage, nonpulsating input current, and grounded bipolar DC bus, which effectively mitigates common‐mode leakage current. This configuration results in a simple and low‐complexity system suitable for applications in PV systems. To validate the theoretical analysis and performance of the proposed inverter, an experimental prototype with a nominal power of 1.5 kW, input voltage of 136 , DC bus of 800 , and output voltage of 220 was developed. The experimental results confirm the expected performance, with a maximum leakage current of only 0.117 mA and peak efficiency of 96.26% operating at 750 W.
No takes yet. Share an insight, caveat, or question.
Vendruscolo et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: