This breakthrough method measures red blood cell stiffness to refine HbA1c testing, indicating significant potential for accuracy in diabetes diagnosis.
Background Glycated hemoglobin (HbA1c) is a critical biomarker for diagnosing diabetes and monitoring diabetes control. Current HbA1c testing methods rely on the quantification of hemoglobin proteins. Therefore, the presence of hemoglobin variants, which are known to differ among racial groups, has been reported to cause inaccurate HbA1c results. This discrepancy is particularly pronounced in point-of-care devices. Additionally, conventional HbA1c tests require complex operations and trained personnel, with accuracy further affected by variations in blood sampling volume. To address these limitations, we propose the world*s first microfluidic-based A1c test, which utilizes single-cell analysis to measure the stiffness of individual red blood cells (RBCs). Methods A microfluidic sensor utilizing MEMS technology was developed, incorporating a microfluidic channel designed to allow the passage of individual RBCs and microelectrode patterns to measure their velocity. A 5 µL capillary blood sample was collected from participants, diluted, and introduced into the microfluidic channel. Over a 5-minute period, the velocities of more than 500 individual RBCs were recorded. Results RBCs from the same individual exhibited varying velocities as they passed through the microfluidic channel. Furthermore, experiments using different dilution ratios of a single blood sample demonstrated that the velocity distribution remained consistent regardless of dilution ratio. Next, we compared the velocity distributions of RBCs from individuals with varying HbA1c levels. Interestingly, RBCs from individuals with higher HbA1c levels exhibited significantly reduced velocities compared to those with lower HbA1c levels. Given the inverse relationship between RBC velocity and cellular stiffness, we confirmed a direct correlation between the mean RBC stiffness, calculated based on cellular velocity, and the participant’s HbA1c level. Conclusion To our knowledge, this is the first study to demonstrate a proportional relationship between HbA1c levels and RBC stiffness. We believe that cellular stiffness measurements have the potential to serve as a groundbreaking metric for A1c testing, offering a method that is from interference from hemoglobin variant and experimental errors.
No takes yet. Share an insight, caveat, or question.
Kang et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: