Understanding the complex three-dimensional (3D) dynamic interactions between self-contained breathing apparatus (SCBA) and the human torso is critical to assessing potential impacts on firefighter health and informing equipment design. This study employed a multi-inertial sensor fusion technology to quantify these interactions. Six volunteer firefighters performed walking and running experiments on a treadmill while wearing the SCBA. Calculations of interaction forces and moments from the multi-inertial sensor technology were validated against a 3D motion capture system. The predicted interaction forces and moments showed good agreement with the measured data, especially for the forces (normal and lateral) and moments (x- and z-direction components) with relative root mean square errors (RMSEs) below 9.4%, 7.7%, 7.7%, and 7.8%, respectively. Peak pack force reached up to 150 N, significantly exceeding the SCBA's intrinsic weight during SCBA carriage. The proposed multi-inertial sensor fusion technique can effectively evaluate the 3D dynamic interactions and provide a scientific basis for health monitoring and ergonomic optimization of SCBA systems for firefighters.
No takes yet. Share an insight, caveat, or question.
Xie et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: