Key result
Full breathing apparatus raises mean heart rate to ~83% of max versus protective clothing alone.
Why the study?
Does wearing a breathing apparatus affect psychophysiological responses and parasympathetic reactivation in firefighters during rescue interventions?
RCT (n=34)
Randomly assigned session order
Does wearing a breathing apparatus affect psychophysiological responses and parasympathetic reactivation in firefighters during rescue interventions?
Wearing a self-contained breathing apparatus during rescue interventions increases psychophysiological stress and cardiac strain in firefighters.
Answers are grounded in this paper and cite their sources.
May heighten cardiac strain during simulated rescues; leaves open real-world effects on firefighter cardiac outcomes.
This study aimed to assess the effect of wearing a breathing apparatus during a simulated rescue intervention on psychophysiological responses and parasympathetic reactivation of firefighters. Thirty‐four firefighters participated in this study which consisted of four experimental sessions conducted randomly: a maximal fitness test and three rescue interventions performed (a) with personal protective clothing ( PPC ); (b) with PPC and the full self‐contained breathing apparatus ( SCBA ), including cylinder, full‐face piece, and breathing regulator; and (c) with PPC and only the cylinder of the self‐contained breathing apparatus ( SCBA c). Physiological (heart rate [ HR ], breathing frequency [ BF ]) and perceptual (rating of perceived exertion [ RPE ]) responses were continuously collected during the three rescue interventions. Parasympathetic reactivation was assessed using HR recovery and variability indexes after experimental sessions. HR responses ranged between 63% and 95% of HR max , and BF responses ranged between 22 and 55 breaths/min for the different activity tasks. Parasympathetic reactivation indexes were similar for the rescue interventions but lower than after the intermittent fitness test ( P = 0.016 – P < 0.0001). Mean HR for both SCBA c (83.2 ± 4.1% HR max ) and SCBA (83.1 ± 5.2% HR max ) was higher in comparison with PPC (79.5 ± 5.3% HR max ). RPE was higher for SCBA than for SCBA c which was higher than PPC . Mean BF for SCBA (34 breaths/min) was lower than PPC (40 breaths/min) and SCBA c (43 breaths/min). Based on HR , BF , and RPE , rescue interventions seem to be psychologically and physiologically stressful. Parasympathetic reactivation after PCC , SCBA , and SCBA c suggests that these conditions induce higher cardiac stress than the maximal fitness test. The study showed that SCBA increased psychophysiological perturbations.
No takes yet. Share an insight, caveat, or question.
Marcel‐Millet et al. (2018) conducted an RCT in Healthy firefighters (n=34). Self-contained breathing apparatus (SCBA) vs. Personal protective clothing (PPC) alone was evaluated on Mean heart rate (% HRmax). Wearing a full self-contained breathing apparatus during simulated rescue interventions increased mean heart rate (83.1% vs 79.5% HRmax) and perceived exertion compared to protective clothing alone.
Synapse has enriched 10 related papers. Consider them for comparative context: