Three-dimensional (3D) isolation is a promising solution for providing comprehensive seismic protection to large-span spatial structures against both horizontal and vertical ground motions. This study introduces an innovative 3D isolation system for spatial reticulated shell structures using pseudo-negative-stiffness magnetorheological dampers (PNSMRDs). In the vertical direction, the PNSMRDs are connected in parallel with a prepressed spring device (PSD)-based bearing (PSDB) to form a PSDB-PNSMRD isolator that supports the reticulated shell roof. A set of semi-active control methods was established for the real-time current input to the PNSMRDs, simulating the related pseudo-negative-stiffness and energy dissipation behaviors of the damping device. A single-layer spherical reticulated shell with surrounding columns was taken as a prototype structure. The PSDB-PNSMRD isolators and concave sliding bearings were designed as a decoupled 3D isolation system for this prototype structure. For comparison, a counterpart 3D isolation system featuring passive viscous dampers was also evaluated. Seismic responses of the isolated and non-isolated structures under triaxial seismic excitations were modeled using an integrated OpenSees‒MATLAB platform. The numerical results reveal that both isolation systems are effective in mitigating structural responses, with the PSDB-PNSMRD bearings providing superior vertical isolation effects compared to passive vertical isolation bearings.
No takes yet. Share an insight, caveat, or question.
Zhuang et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: