Answers are grounded in this paper and cite their sources.
The Iowa Test of Consonant Perception (ITCP) is a single-word closed-set speech- in-noise test with well-balanced phonetic features that provides a reliable testing option for real-world listening. Objectives. The current study aimed to establish a UK version of the test (B-ITCP) based on the British received pronunciation. Design. We conducted a validity test with 46 participants using the B-ITCP test, a sentence-in- noise test, and audiogram. Results. The B-ITCP demonstrated excellent test-retest reliability, cross-talker validity, and good convergent validity, consistent with the US results. Conclusions. These findings suggest that B-ITCP is a reliable measure of speech-in-noise perception, to facilitate comparative or combined studies in USA and UK. All materials (application and scripts) to run or construct the B-ITCP and ITCP are freely available online.
No takes yet. Share an insight, caveat, or question.
Guo et al. (2024) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: