Answers are grounded in this paper and cite their sources.
Excess hypochlorite (ClO − ) is harmful to living organisms and can cause various oxidative diseases in the human body. Owing to the toxicity of ClO − , the development of efficient fluorescence sensors to track ClO − is necessary. In this work, we report a novel thiourea‐based fluorescent turn‐on sensor 1‐(9‐ethyl‐9 H ‐carbazol‐3‐yl)‐3‐(naphthalen‐1‐yl)thiourea ( ECNT ) for recognizing ClO − . ECNT can detect ClO − with high selectivity, relatively low interference with other analytes, and a significantly fast response time (<1 s) through a desulfurization reaction. The detection limit of ECNT for ClO − is calculated as 5.59 μM. Of note, ECNT is a chemosensor that reacts the fastest with ClO − among the reported thiourea‐based fluorescence turn‐on sensors for detecting ClO − . The response mechanism of ECNT to ClO − is demonstrated through 1 H NMR titration, ESI mass, and density functional theory calculations.
No takes yet. Share an insight, caveat, or question.
Choi et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: