Purpose: Testing samples of cotton materials for their use as objects of recovery of accumulated dose by EPR dosimetry. Material and methods: Samples of cotton fabric and fabrics of mixed composition – lab coats, casual clothing items – shirts and jeans, as well as protective masks and respirators were irradiated using a linear electron accelerator model UELR-10-10C2 in the dose range from several Gy to 16 kGy. EPR spectra were recorded using the Bruker Elexsys-II E580 X-band EPR spectrometer with a SuperHighQ cylindrical resonator. Results: It was found that ionizing radiation induces free radicals in materials with triplet EPR signal, the most intense line of which has g = 2.019 and a linewidth 6 G. There was no or negligible native signal in uncolored fabrics. The radiation-induced EPR signal decayed exponentially with average half-life time of 62 hours. Conclusion: Clothing materials based on cotton fabrics, as well as materials of protective medical masks, have shown themselves suitable for use as an object of retrospective EPR dosimetry.
No takes yet. Share an insight, caveat, or question.
Ivanov et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: