The development of micro-hot-wire anemometry probes for turbulence studies requires mitigating spatial filtering, end-conduction effects and probe intrusivity. Keeping these factors in mind, this work analytically and experimentally investigates the relevance of a micro-hot-wire probe design featuring elongated stubs, inspired by Wollaston-wire probes but fabricated using modern micro-fabrication techniques. The resulting probes are shown to be relatively easy to manufacture and capable of providing satisfactory velocity measurements in a zero-pressure-gradient turbulent boundary layer at Reτ≈ 1150 with δ =18mm . Different probes were tested, all featuring a micro-wire length sufficiently small to alleviate spatial filtering of near-wall small-scale turbulent structures. The investigation focuses on assessing end-conduction effects and probe intrusivity, with the latter still observable close to the wall for such micro-probes.
No takes yet. Share an insight, caveat, or question.
Baradel et al. (2024) studied this question.