This is the authors' abstract. We don't add key points for this paper.
Issues concerning the accuracy of hot-wire measurements in turbulent pipe flow are addressed for pipe Reynolds numbers up to 6 × 10 6 and hot-wire Reynolds numbers up to Re w ≈ 250. These include the optimization of spatial and temporal resolution and the associated feature of signal-to-noise ratio. Very high wire Reynolds numbers enable the use of wires with reduced length-to-diameter ratios compared to those typical of atmospheric conditions owing to increased wire Nusselt numbers. Simulation of the steady-state heat balance for the wire and the unetched portion of wire are used to assess static end-conduction effects: they are used to calculate wire Biot numbers, , and fractional end-conduction losses, σ, which confirm the 'conduction-only' theory described by Corrsin. They show that, at Re w ≈ 250, the wire length-to-diameter ratio can be reduced to about 50, while keeping and σ < 7% in common with accepted limits at Re w ≈ 3. It is shown that these limits depend additionally on the choice of wire material and the length of unetched wire. The dynamic effects of end-cooling are also assessed using the conduction-only theory.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Li et al. (2004) studied this question.