Air staging in solid fuel combustion features widely in small scale domestic boilers to large scale moving grate combustors. Whilst the effects of air staging on the combustion characteristics of these systems are generally known, there is very little insight available into the role of secondary air on the flow and temperature field in the freeboard of batch-type fixed bed biomass combustors. Three-dimensional gas phase simulations using the Transition 𝑘kl-𝜔 and Finite Rate/Eddy Dissipation models were validated against freeboard temperatures and emissions (CO 2 and O 2 ) measured on the same set-up. Results show that secondary air at Q s /Q t ≥0.25 induces two recirculation zones, upstream and downstream of its injection point with maximum freeboard temperatures generally observed around these recirculation zones, if Q s /Q t drops to 0.12-0.18 only an upstream recirculation zone is observed until it diminishes by Q s /Q t = 0.06. However, there is a trade-off caused by what appears to be a cooling effect if Q s /Q t is increased between 0.25 and 0.71. Modelling results show that in reacting cases, unlike non-reacting modelling on the same geometry, the strength of the secondary air induced upstream recirculation zone appears significantly stronger.
No takes yet. Share an insight, caveat, or question.
Junejo et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: