Answers are grounded in this paper and cite their sources.
Calcified lesions are associated with higher rates of complications during percutaneous coronary intervention (PCI). Balloon shaft fracture and entrapment is a rare, but potentially severe complication of PCI. The resulting debris might lead to vessel occlusion and/or form a pro-thrombotic nidus, potentially leading to distal embolization, acute myocardial infarction, ventricular dysrhythmia, and even death. We report a case of balloon fracture and entrapment, where rotational atherectomy was essential in modifying the entrapped material, allowing the crossing of an otherwise uncrossable "balloon-lesion complex", subsequently treated with crushing and jailing by stenting, with good angiographic result and outcome. Calcified lesions are associated with higher rates of complications during percutaneous coronary intervention (PCI). Balloon shaft fracture and entrapment is a rare, but potentially severe complication of PCI. The resulting debris might lead to vessel occlusion and/or form a pro-thrombotic nidus, potentially leading to distal embolization, acute myocardial infarction, ventricular dysrhythmia, and even death. We report a case of balloon fracture and entrapment, where rotational atherectomy was essential in modifying the entrapped material, allowing the crossing of an otherwise uncrossable "balloon-lesion complex", subsequently treated with crushing and jailing by stenting, with good angiographic result and outcome. A 78-year-old male, with previous coronary artery bypass graft surgery 12-years prior [left internal mammary artery (LIMA) to left anterior descending artery (LAD); saphenous venous graft (SVG) to first obtuse marginal branch (OM1); and SVG to posterior descending artery (PDA) bypass grafts], was admitted for high-risk non-ST segment elevation myocardial infarction. Echocardiography demonstrated a left ventricle ejection fraction of 35%. Coronary artery and bypass graft angiography showed left coronary territory perfused by patent LIMA-LAD and SVG-OM1 grafts; SVG-PDA graft occlusion at its origin; mid right coronary artery (RCA) long, heavily calcified critical stenosis, posterolateral artery (PLA) critical stenosis; and PDA chronic total occlusion. Although initially managed conservatively, the patient was referred to our center for RCA and PLA percutaneous coronary intervention (PCI) due to recurrent angina. The planned procedure was to perform rotational atherectomy (RA) to prepare mid RCA lesion for subsequent angioplasty. The RCA showed a de novo TIMI 2 flow and an intermediate ostial lesion (Figure 1A), with the remaining lesions unchanged. Due to high-risk of no-flow after RA in a TIMI 2 flow status, we decided to not perform RA. First, semi-compliant (SC) balloon dilation was performed on the mid RCA lesion. Then, under the support of a 6F GuideZilla II (Boston Scientific, Marlborough, MA), guide support extension catheter, the PLA lesion was uneventfully treated with one 3.0 x 40mm drug-eluting stent (DES) (Figure 1B). Afterwards, we proceeded to mid-RCA lesion preparation with multiple pre-dilatation cycles with SC balloons of increasing caliber (Figure 1C). While retracting a 4.0 x 15mm Ikazuchi (Kaneka, Cordis, Hialeah, FL) SC balloon into the GuideZilla II, resistance was found, immediately followed by documentation of shaft fracture, with distal separation from the proximal end of the balloon, with embolization and entrapment in the mid-RCA lesion (Figure 1D). Despite this complication, a TIMI 2 flow was still maintained. At the time, we considered multiple techniques to retrieve the embolized material, namely trapping balloon technique, twisting wire technique, and snare technique (Figure 1E); however, trapping balloon technique was not possible due to shaft's absence (Figure 1F); and the other two techniques could not be performed because the lesion was uncrossable. At this point, during the attempts to retrieve the entrapped balloon, an iatrogenic RCA ostial dissection occurred and was treated with direct stenting using 5.0 x 24 mm DES. Firstly, balloon crushing was attempted, nonetheless, it was impossible to overcome the "balloon-lesion complex" with balloons larger than 1.5mm, and immediate recoil was present when smaller balloons where used (Figure 2A), with no change in TIMI flow. Considering the current scenario, we decided to return to our original plan: we advanced a Corsair Pro microcatheter (Ashai Intecc Co., Japan) with extreme difficulty, allowing guidewire exchange for RotaWire Floppy (Boston Scientific, Marlborough, MA); then proceeded with RA using a 1.25mm burr (Boston Scientific, Marlborough, MA), with successful rotablation after multiple runs at 180.000 rpm (Figure 2B; Supplemental Video S1). Then, we were able to advance material and cracked the "balloon-lesion complex" with 4.0mm non-compliant (NC) Emerge balloon (Boston Scientific, Marlborough, MA), proceeding with three consecutive stents (4.0 x 40mm, 4.5 x 32mm and 5.0 x 15mm DES), from the previously implanted PLA stent to the previously implanted ostial RCA stent (Figure 2C-E). In the end, there was good final angiographic result (Figure 2F and Supplemental Video S2) with no evidence of distal embolization during or post rotablation. Both in-hospital and 12-month follow-up were uneventful. As the number of PCI procedures in high risk and complex settings increase, a parallel increase in complications is also expected. The risk of PCI complication by broken/entrapped angioplasty material is estimated in 0.1%, reaching 1.5% in complex procedures such as chronic total occlusions1Iturbe J.M. Abdel-Karim A.R. Papayannis A. et al.Frequency, treatment, and consequences of device loss and entrapment in contemporary percutaneous coronary interventions.J Invasive Cardiol. 2012; 24: 215-221PubMed Google Scholar,2Gasparini G.-L. Sanz-Sanchez J. Regazzoli D. et al.Device entrapment during percutaneous coronary intervention of chronic total occlusions: Incidence and management strategies.EuroIntervention. 2021; 17: 212-219https://doi.org/10.4244/eij-d-20-00781Crossref PubMed Scopus (0) Google Scholar. Overall, disrupted balloon shafts are rare (possibly underreported) events3Chang W.-T. Chen J.-Y. Li Y.-H. Tsai L.-M. Lee C.-H. A two-case series of entrapment of a ruptured balloon in the coronary artery: Avoidable complications and nonsurgical management.Journal of the Formosan Medical Association. 2015; 114: 1135-1139https://doi.org/10.1016/j.jfma.2013.05.008Crossref Scopus (11) Google Scholar. All recommended retrieval and fragmentation techniques for the management of this dreadful complication are based on the need to crosswire the trapped material or cannot be undertaken in case of shaft absence2Gasparini G.-L. Sanz-Sanchez J. Regazzoli D. et al.Device entrapment during percutaneous coronary intervention of chronic total occlusions: Incidence and management strategies.EuroIntervention. 2021; 17: 212-219https://doi.org/10.4244/eij-d-20-00781Crossref PubMed Scopus (0) Google Scholar,4Sanz‐Sánchez J. Mashayekhi K. Agostoni P. et al.Device entrapment during percutaneous coronary intervention.Catheterization and Cardiovascular Interventions. 2022; 99: 1766-1777https://doi.org/10.1002/ccd.30160Crossref Scopus (6) Google Scholar. Unfortunately, in our case, there was no shaft remaining in the entrapped material and the lesion proved to be uncrossable. At the time, we also did not consider the possibility to release fractured balloon via sub-intimal plaque modification technique. We speculate that the multiple cycles of inflation-deflation of a large diameter balloon led to its damaging and, probably, suboptimal deflation, making it prone to fracture during its retraction. Tortuosity, angulation, and lesion calcification are risk factors for device entrapment during PCI1Iturbe J.M. Abdel-Karim A.R. Papayannis A. et al.Frequency, treatment, and consequences of device loss and entrapment in contemporary percutaneous coronary interventions.J Invasive Cardiol. 2012; 24: 215-221PubMed Google Scholar. All these factors were considered in the original planning of the procedure: preparing the lesion with RA. However, common complications of RA include coronary artery spasm, coronary artery dissection, rotational head incarceration, the slow-flow/no-reflow phenomenon and perforation5Tomey M.I. Kini A.S. Sharma S.K. Current status of rotational atherectomy.JACC: Cardiovascular Interventions. 2014; 7: 345-353https://doi.org/10.1016/j.jcin.2013.12.196Crossref PubMed Scopus (235) Google Scholar,6Barbato E. Carrié D. Dardas P. et al.European expert consensus on rotational atherectomy.EuroIntervention. 2015; 11: 30-36https://doi.org/10.4244/eijv11i1a6Crossref PubMed Scopus (0) Google Scholar. Indeed, the RCA slow-flow is a major predictor of no-flow status after RA, which was the main reason for our initial intraprocedural strategy change. We here present an approach consisting in atherectomy-based modification of the fractured/embolized fragment, consistent with a previous report by Balasubramaniam et al7Balasubramaniam K. Elbarouni B. Kass M. Minhas K. Ravandi A. Rotational atherectomy in the management of ruptured and entrapped coronary angioplasty balloon.Cardiovascular Revascularization Medicine. 2021; 28: 140-143https://doi.org/10.1016/j.carrev.2020.09.039Crossref Scopus (1) Google Scholar. In this case, due to the large dimensions of the entrapped balloon, we did not attempt a complete pulverization of the embolized fragment with RA, but rather a modification just enough to cross it and proceed with crushing and jailing with stenting. Also, due to persistent entrapment after RA, balloon extraction by snaring was not attempted due to the low probability of success and added risk of dissection. Given the unpredictability of the size of the pulverized fragments and their final location after RA, this technique must be considered only as a bailout option until additional reports further define its merits and risks. •Complex, tortuous, and heavily calcified lesions raise the risk for device entrapment during PCI, a potentially life-threatening situation.•Balloon fracture is a rare complication, but likely to be underreported.•In the face of this complication, the recommended first line strategies2Gasparini G.-L. Sanz-Sanchez J. Regazzoli D. et al.Device entrapment during percutaneous coronary intervention of chronic total occlusions: Incidence and management strategies.EuroIntervention. 2021; 17: 212-219https://doi.org/10.4244/eij-d-20-00781Crossref PubMed Scopus (0) Google Scholar, 3Chang W.-T. Chen J.-Y. Li Y.-H. Tsai L.-M. Lee C.-H. A two-case series of entrapment of a ruptured balloon in the coronary artery: Avoidable complications and nonsurgical management.Journal of the Formosan Medical Association. 2015; 114: 1135-1139https://doi.org/10.1016/j.jfma.2013.05.008Crossref Scopus (11) Google Scholar, 4Sanz‐Sánchez J. Mashayekhi K. Agostoni P. et al.Device entrapment during percutaneous coronary intervention.Catheterization and Cardiovascular Interventions. 2022; 99: 1766-1777https://doi.org/10.1002/ccd.30160Crossref Scopus (6) Google Scholar should be followed, considering the individual case characteristics and operator experience.•In extreme cases the lesion can prove to be uncrossable, limiting rescue strategies.•As a bail-out technique, RA can be effective in partially pulverizing the balloon-lesion complex and allowing lesion crossing, dilation, and jailing by stenting. The authors declare that they have no conflicts of interest to report regarding the present study. The authors received no specific funding for this study.
No takes yet. Share an insight, caveat, or question.
Sá‐Couto et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: