Key result
Stepwise guide extension and balloon trapping successfully retrieves an entrapped, ruptured coronary balloon fragment.
Why the study?
Published bailout strategies for balloon catheter fracture during PCI typically address shaft fracture, undeflatable balloon, and entrapped balloon in isolation, with no specific guidance when multiple forms occur simultaneously.
Case Report (n=1)
No
Demonstrates a sequential percutaneous bailout technique using distal displacement via a guide extension catheter and straddle-trapping to safely resolve simultaneous balloon shaft fracture, deflation failure, and intracoronary entrapment during PCI.
Alerts operators to concurrent multi-form balloon fractures in PCI; leaves open standardized bailout protocols for this rare complication.
Background Balloon catheter fracture during percutaneous coronary intervention (PCI) is rare but potentially catastrophic. The literature describes three distinct forms: shaft fracture, undeflatable balloon, and entrapped balloon. Published bailout strategies typically address each problem in isolation; however, no specific guidance exists when multiple forms occur simultaneously. Case summary A 62-year-old man with multivessel coronary disease underwent staged PCI of an a left circumflex–obtuse marginal bifurcation. During lesion preparation, a reused semi-compliant balloon (2.5 × 14 mm) fractured after multiple inflations, leaving an inflated, entrapped balloon fragment at the bifurcation with impaired antegrade flow. A stepwise percutaneous bailout was performed: (1) length comparison with an intact reference balloon suggested that a long fragment was partly retained inside the guiding catheter; (2) a guide extension catheter was advanced to displace the fragment distally, achieving passive deflation and restoring flow; and (3) the deflated fragment was retrieved using a 2.0 mm trapping balloon straddling the tip of the guiding catheter. The procedure was completed successfully with stenting, and the patient recovered uneventfully. Discussion Sequential management converted a high-risk situation into a tractable single problem. Distal displacement of the inflated fragment relieved ischaemia before any retrieval attempt was made. Trapping with a second balloon straddling the guide catheter tip may improve grip when the fragment partly protrudes from the guiding catheter.
No takes yet. Share an insight, caveat, or question.
Nguyen et al. (2026) conducted a case report in Multivessel coronary disease complicated by balloon catheter fracture, deflation failure, and intracoronary entrapment during PCI (n=1). Stepwise percutaneous bailout (guide extension catheter distal displacement and 2.0 mm trapping balloon retrieval) was evaluated on Successful retrieval of the entrapped balloon fragment, restoration of coronary flow, and procedural completion. A stepwise percutaneous bailout using a guide extension catheter and a 2.0 mm trapping balloon successfully deflated and retrieved an entrapped 2.5 × 14 mm balloon fragment in 1 patient.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: