We assessed the prognostic potential of Galectin-3 in a sample of 159 heart failure patients who received a left ventricular assist device (LVAD) implant from 2012 to 2020. Clinical outcomes included hemodynamic data, right heart failure (RHF), hemocompatibility-related adverse events (HRAEs), and mortality. Galectin-3 was compounded into Michigan-RVF and EUROMACS-RHF risk scores and compared to the noncompounded risk scores. Right heart failure was significantly correlated with Galectin ( p = 0.004) on a continuous spectrum. Inotrope duration was significantly correlated to Galectin-3 (interquartile range [IQR]: 7.58–8.65, p < 0.001) along with INTERMACS score (IQR: 2.14–1.90, p < 0.001). Intensive care unit length of stay (median 8 days, p = 0.02), blood urea nitrogen ( p < 0.001), creatinine ( p < 0.001), and pulmonary artery pulsatility index ( p = 0.05) were also significantly correlated with Galectin-3. In our c-statistic analysis, the predictive value for RHF improved when Galectin-3 was included for both the Michigan-RVF (0.80–0.86) and EUROMACS-RHF (0.77–0.82) risk scores. When elevated over a binary cutoff of 18.2 ng/ml, Galectin-3 significantly correlated with HRAEs ( p = 0.014) and mortality ( p = 0.031). Galectin-3 shows great promise as a predictive biomarker in patients implanted with durable LVADs. In addition to significant correlation with key clinical outcomes, Galectin-3 enhanced the Michigan-RVF and EUROMACS-RHF risk scores in predicting progression to RHF.