Answers are grounded in this paper and cite their sources.
Device Day was created to provide registered nurses an opportunity to manipulate vital equipment used in cardiac intensive care units (ICUs). Nurses complete hands-on skills with fully functioning devices to increase exposure in a safe environment with no patient risk. To date, we have incorporated 7 high-risk devices frequently used in cardiac ICUs into Device Day (Table 1).Cardiac ICU nurses at our quaternary health system routinely care for acutely ill patients with cardiac assist devices and other critical pieces of equipment, including mechanical circulatory support (MCS). Many large facilities have dedicated MCS specialists who provide direct oversight of cardiac assist devices alongside the primary nurse, resulting in a 2:1 nurse-patient ratio. Alternatively, nurses at this hospital are trained to manage devices as the expert and primary nurse in collaboration with the medical team.After initial training, nurses reported varying levels of exposure with MCS and other high-risk devices due to their unit patient population and requested additional hands-on opportunities with the equipment. In addition, nurse leaders expressed concern that some newly trained device nurses did not have frequent opportunities to clinically apply skills. With support from nursing leadership, a task force of 2 clinical nurse specialists designed Device Days as a sustainable solution to provide additional hands-on opportunities with high-risk cardiac assist and invasive devices.Adults learn best when content is relevant to their clinical practice, builds on current skills and experiences, and helps the learner achieve their objectives.1 Additionally, the Extracorporeal Life Support Organization recommends water drills for extracorporeal membrane oxygenation (ECMO)–trained staff.2 These adult learning principles were used to design Device Day.After identifying the required stations, the Device Day task force identified critical skills to be performed at each station. Consideration was given to the fact that multiple companies produce equipment, so all product versions were made available. A brief overview of skills reviewed at each station is available in Table 1. All applicable devices were fully functional to increase exposure to realistic scenarios in a low-fidelity simulation environment. For example, ECMO circuits were primed with solution and were operational, and all alarms were on.A pool of skilled facilitators was recruited to run stations and included clinical nurse specialists, assistant nurse managers, and a nursing professional development specialist. Device Day sessions were offered for 3.5-hour increments, 10 times annually. The target audience included all nurses who received initial training for designated critical care devices.To prepare for Device Day, the equipment was obtained and organized the day prior. Nurses were required to sign in to each station for tracking purposes. As nurses performed critical skills listed in facilitator checklists, they had to provide the rationale for their actions. The facilitator checklist ensured consistent content delivery and aided in standardization of the activity. Each station took approximately 10 to 35 minutes to complete, depending on the nurse's experience and the number of skills reviewed.To make Device Day sessions more accessible during working hours, multiple dates were offered, and an open attendance format was used to allow for walk-ins rather than scheduling sessions beforehand. The volume at each session fluctuated because nurses did not select a date in advance for attendance and could attend more than 1 session.In the initial rollout of Device Day sessions, most participants attended only mandatory stations, and we did not track the other stations. Facilitators actively encouraged nurses to attend a station that was less busy while they waited for availability of the mandatory station. Those who participated in the non-mandatory stations reported that they were thankful for the opportunity.Moving forward, facilitators were challenged with increasing attendance at nonmandatory stations. As a result, the team began promoting Device Day in all the MCS classes for newly device-trained nurses. Additionally, the facilitators started requiring sign-in sheets at each station. If a nonmandatory station had low attendance, it was evaluated for removal.In 2023, we had 564 encounters across 7 stations. Although we did not track the number of individual nurses in attendance, we did track attendance at each station. Device Day encounters are captured in Table 2.At the end of year 1, 8 participants completed a voluntary electronic survey to provide feedback on Device Day. Based on a 5-point Likert scale, participants indicated that sessions were organized (mean, 4.0 [SD, 0.8]), had an adequate number of stations (mean, 4.0 [SD, 0.6]), and were held in an accessible location (mean, 4.1 [SD, 0.8]). Participants had mixed opinions on whether the amount of space to complete stations was adequate (mean, 4.0 [SD, 1.1]). Some of the sessions were in a large hall and some in smaller rooms, so further evaluation will be needed.Participants valued the opportunity to practice emergency skills that were relevant to their units and appreciated hands-on opportunities with ECMO circuits. Feedback included the request to have Device Day hosted in the ICUs for additional convenience; as such, roving ECMO stations will occur throughout the year between scheduled Device Day sessions as an added resource to increase exposure to equipment. The rapid infuser has also been added to the list of available stations, per request.A survey has been developed to gather real-time feedback at each station from future participants. Facilitators hope to glean insight into the impact of each station and how to modify the experience to meet the needs of the participants.The Device Day concept can be adapted to meet the needs of the nursing team in any care area by incorporating high-risk devices or skills to increase hands-on exposure. There is not a recommended number of tasks or procedures to include; however, time and resources must be considered. Planners must be mindful of the time it will take participants to complete all stations and have an adequate number of content experts to facilitate stations. Establishing an evaluation process before implementation is suggested to assess feedback in real time and make the experience the most meaningful.
No takes yet. Share an insight, caveat, or question.
Jividen et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: