Excessive sulfur dioxide (SO₂) disturbs physiology of lysosomes causing diseases and threatening human health. A fluorescent probe has been regarded as one of the most attractive approaches, which is compatible with living cells and possesses high sensitivity. However, most of fluorescent probes’ reaction sites are activated before they reach the destination. In this work, an acid‐activatable fluorescent probe PT1 was synthesized, characterized, and used for SO 2 detection. The introduction of oxazolines in PT1 enables the intelligent response of probe to release the activation stie for SO 2 derivatives through Michael addition upon exposure to acid. In vitro studies showed a remarkable selectivity of PT1 to SO₂ derivatives than other biothiols with a limit of detection as low as 62 nM. By using this acidic pH‐controlled fluorescence responsiveness to SO₂, precise spatiotemporal identification of lysosomal SO 2 fluctuations has been successfully performed. Furthermore, probe PT1 can be applied for monitoring SO₂ derivatives in traditional Chinese medicines.
No takes yet. Share an insight, caveat, or question.
Xi et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: