Answers are grounded in this paper and cite their sources.
Among the three different electromagnetic fields associated with magnetic resonance imaging (MRI), the powerful static magnetic field, a salient feature of the MR system, is invariably the focus of safety, primarily because of its potential to cause serious injuries, fatalities, and substantial damage to MR scanners by attracting ferromagnetic objects (i.e., projectile-related events).1-4 Thus, throughout the history of clinical MRI, preventing inadvertent access to the MR system room has always been integral to ensuring the safety of patients, staff members, and others.1-4 Another concern of the MR system's static magnetic field is the unintended programming of certain active implants (e.g., specific types of cardiac pacemakers, implantable cardioverter defibrillators, and neuromodulation systems), namely, those that incorporate reed switches or Hall-effect sensors to detect and respond to low magnetic fields to control therapy.5-7 These active implants are programmed into a "magnet mode" or other attribute by means of an external, hand-held magnet, the therapeutic impact of which depends on the particular active implant.7 Accordingly, an individual with one of these medical products may experience unanticipated consequences, including cessation of therapy, if unintentionally exposed to a relatively low magnetic field.6, 7 In light of this, during the early implementation of MRI technology, the 5 gauss (0.5 mT) line or area was established as the threshold for risk.3, 7, 8 Notably, during my nearly 40 years of involvement with MRI, I am unaware of anyone with an active implant, with a reed switch or Hall-effect sensor, experiencing a deleterious event due to accidental exposure to a 5 gauss or higher magnetic field in association with the MRI environment. A recent review by Steckner et al,7 examined the fascinating history of the 5 gauss (0.5 mT) threshold for protecting against inadvertently placing certain active implantable medical devices into a "magnet mode" or another programming feature. In their noteworthy paper, the authors effectively described the interesting background of the increase from the 5 gauss to the 9 gauss level in the standard, International Electrotechnical Commission (IEC) 60601-2-33, that defines basic safety requirements for MRI,8 along with the practical implications of this change, which include decreased installation costs and improved siting flexibility [Correction added on 13 July 2024, after first online publication: Preceeding line has been amended.].7 Their review also discussed the ongoing and emerging issues associated with the new 9 gauss threshold, including those related to consumer electronics.7 During my exploration of the origin of the 5 gauss threshold, I encountered (with special thanks and acknowledgement to Gregory Hurst) the following excerpt in a book of historical accounts from iconic, MRI pioneers, including the inimitable, Professor Ian Young, who stated9: "But to illustrate our ignorance this is my story of how the '5 gauss line' came about—because there are probably at least 97 other ones. I told this story at a safety conference, with the FDA there, a couple of weeks ago. It's one of Gordon Higson's initiatives in a sense. John Williams had a research student who was going to work for him for about six weeks one summer. I think it must have been in 1978 and John couldn't think of anything for him to do and finally he said 'Here is a list of all the pacemakers we know about and here's a magnet, find out which ones fail at what field'. John had told me about three weeks before that he thought that most of them had worked quite well down to about 5 gauss with one he thought would fail below 5 gauss. I was phoned up by the FDA one Friday afternoon my time, Friday morning in America, by a young woman who went on to become a clinician. She was then working for the FDA as a very, very, very junior physicist and this was the status they were giving the issue. This was the bottom of the pan—the FDA were really monumentally uninterested in the topic—but she enquired about stray fields and what they do. I said they are present around magnets and cause plenty of artefacts and problems unless you are careful. For example, they affect CRTs (cathode-ray tubes); and she said, 'Are they unsafe?' I said, 'I don't know'. We use them often enough. The only unsafe thing I knew about is this experiment John Williams had done at the Department of Health and Social Security (DHSS). He'd put magnets besides pacemakers and found 5 gauss mostly all right. And that's where the 5 gauss line came from. Quite as anecdotal and stupid as that and it's still there and nobody can get rid of it." Is this how a critical threshold intended to prevent issues for a relatively small number of individuals with active implants may have been created for MRI safety? On another matter related to the original 5 gauss threshold for risk, based on my numerous personal communications with members of the MRI community over the years, I realized that these healthcare professionals often erroneously believed that the 5 gauss area exists because of concerns related to ferromagnetic objects becoming projectiles. In fact, the 5 gauss area has nothing to do with risks associated with projectile events. As Steckner et al.7 specifically indicated in their review, the 5 gauss (or 9 gauss) threshold has never been about projectiles [Correction added on 13 July 2024, after first online publication: The preceeding sentence has been modified.]. Its focus was always to ensure that individuals with certain active implants did not inadvertently enter an area that resulted in their implants changing into the magnet mode. Hopefully, with this Commentary and the recent information presented by Steckner et al.,7 we can now put that matter to rest.
No takes yet. Share an insight, caveat, or question.
Frank G. Shellock (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: