Answers are grounded in this paper and cite their sources.
Even with the powerful statistical parameters derived from the Extreme Gradient Boost (XGB) algorithm, it would be advantageous to define the predicted accuracy to the level of a specific case, particularly when the model output is used to guide clinical decision-making. The probability density function (PDF) of the derived intracranial pressure predictions enables the computation of a definite integral around a point estimate, representing the event’s probability within a range of values. Seven hold-out test cases used for the external validation of an XGB model underwent retinal vascular pulse and intracranial pressure measurement using modified photoplethysmography and lumbar puncture, respectively. The definite integral ±1 cm water from the median (DI ICP ) demonstrated a negative and highly significant correlation (-0.5213±0.17, p< 0.004) with the absolute difference between the measured and predicted median intracranial pressure (Diff ICPmd ). The concordance between the arterial and venous probability density functions was estimated using the two-sample Kolmogorov-Smirnov statistic, extending the distribution agreement across all data points. This parameter showed a statistically significant and positive correlation (0.4942±0.18, p< 0.001) with Diff ICPmd . Two cautionary subset cases (Case 8 and Case 9), where disagreement was observed between measured and predicted intracranial pressure, were compared to the seven hold-out test cases. Arterial predictions from both cautionary subset cases converged on a uniform distribution in contrast to all other cases where distributions converged on either log-normal or closely related skewed distributions (gamma, logistic, beta). The mean±standard error of the arterial DI ICP from cases 8 and 9 (3.83±0.56%) was lower compared to that of the hold-out test cases (14.14±1.07%) the between group difference was statistically significant (p<0.03). Although the sample size in this analysis was limited, these results support a dual and complementary analysis approach from independently derived retinal arterial and venous non-invasive intracranial pressure predictions. Results suggest that plotting the PDF and calculating the lower order moments, arterial DI ICP , and the two sample Kolmogorov-Smirnov statistic may provide individualized predictive accuracy parameters.
No takes yet. Share an insight, caveat, or question.
Abdul‐Rahman et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: