This study investigates the impact of needle peening (NP) on the fatigue strength of aluminum alloy welded joints with an artificial semicircular slit at the weld toe. Uniaxial fatigue tests were performed on specimens, both with and without a slit, at a stress ratio of 0.05. The fatigue strength at 2 million cycles increased by 11%–100% due to NP treatment. Notably, specimens with 1.0 mm slit depths demonstrated fatigue strengths equivalent to those without a slit, attributed to the introduction of substantial deep compressive residual stresses. This finding suggests that NP can effectively mitigate semicircular slits less than 1.0 mm, enhancing the reliability of aluminum alloy welded joints. Such slits, typically challenging to detect via standard nondestructive inspections, can be addressed efficiently through NP.
No takes yet. Share an insight, caveat, or question.
Ryutaro Fueki (2024) studied this question.