The high-efficient cooling structure is one of the key basic problems in the design of the highly integrated in-wheel motor (IWM) drive system. A 15 kW IWM drive system with the spiral cooling structure is taken as the research object in this article. First, the thermal characteristics under different conditions are analyzed based on the modeling and the heat source determination of the IWM drive system. Second, the highest temperature of insulation and permanent magnet and temperature difference of insulation are taken as optimization objectives. The inlet flow rate, the inlet and outlet diameters, the channel numbers, the channel height, and the channel ribs thickness of cooling structure are taken as optimization parameters to optimize based on the designed experiments, the multivariate linear regression equation and PSO method. Finally, the optimization results are verified by comparing the temperature field before and after optimization. The results show that the optimized structure can achieve better effect. The highest temperature of insulation, the highest temperature of permanent magnet and the temperature difference of insulation of IWM decreased by 9.27%, 9.52%, and 20.93%, respectively. This research work can provide some ideas and methods for the optimization design of cooling structure of IWM drive system.