Our objectives were to develop and evaluate an integrated system consisting of a lateral-flow immunoassay (LFIA) and an electronic portable imaging device for determination of pregnancy status of cows based on plasma concentrations of pregnancy-specific protein B (PSPB). Experiment 1 was conducted to test the performance of the LFIA for PSPB (PSPB-LFIA) whereas experiment 2 was conducted to evaluate the performance of the integrated system including both the LFIA and imaging device. The PSPB-LFIA strips were made of nitrocellulose membrane with polystreptavidin, anti-mouse antibody, Europium-anti-PSPB conjugates, and biotin-PSPB. After adding buffer and plasma in a 96-well plate, strips were dipped to initiate flow and were read in a fluorescence microscope to estimate PSPB concentrations based on the test-to-control line signal (T/C ratio). The T/C ratio of standards was linearly associated with PSPB (R2 = 0.99 in both experiments) concentrations. To test the ability to identify pregnant cows of the PSPB-LFIA only or the integrated system, plasma samples were collected and transrectal ultrasonography (TUS) was conducted 29 to 35 d post AI in lactating Holstein cows (Experiment 1: n = 83; Experiment 2: n = 205). A cow was considered pregnant (Preg) if concentrations of PSPB in plasma obtained by ELISA were ≥2 ng/mL or if an embryo was visible by TUS. In Experiment 1, the accuracy of the PSPB-LFIA compared with ELISA was 92.7% (91.2% Se; 96.1% Sp; 98.1% PPV; 83.3% NPV) and compared with TUS was 90.4% (100% Se; 78.9% Sp; 84.9% PPV; 100% NPV). The agreement between LFIA and ELISA (kappa = 0.84; 95%CI 0.71–0.96) or LFIA and TUS (kappa = 0.80; 95%CI 0.67–0.93) as methods to classify cows as Preg or Non-Preg was high. In Experiment 2, the accuracy of the PSPB-LFIA compared with ELISA was 96.1% (93.8% Se; 100% Sp; 100% PPV; 90.5% NPV) and compared with TUS was 92.2% (99.0% Se; 84.7% Sp; 87.6% PPV; 98.8% NPV). The agreement between LFIA and ELISA (kappa = 0.92; 95%CI 0.86–0.97) or LFIA and TUS (kappa = 0.84; 95%CI 0.77–0.92) as methods to classify cows as Preg or Non-Preg was high. We conclude that a system integrating a fluorescence-based LFIA and an optical reader was effective for classifying cows as pregnant or not pregnant based on estimations of plasma concentrations of PSPB. This novel system serves as a platform for further development of on-farm pregnancy testing tools based on measurement of biomarkers of pregnancy in bodily fluids of cattle.
No takes yet. Share an insight, caveat, or question.
Rial et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: