Answers are grounded in this paper and cite their sources.
The need for reliable bonded interface materials is critical to realize the performance benefits of wide-bandgap devices in power electronics modules, especially in operating temperatures greater than 150°C. In this paper, we investigate the thermomechanical performance of sintered copper (Cu) as a large-area attachment, bonded between Cu baseplates and active-metal-bonded substrates, under accelerated thermal shock (−40°C to 200°C) conditions. In the fabrication phase of the samples, we used different stencil patterns and found that the grid and stripe patterns resulted in a better outgassing of the residual organics during the sintering process, thereby ensuring a substantially improved bond quality compared to a full-area print. The paste consisted of Cu microflakes, and we performed sintering using a Budatec SP300 sintering press at 275°C with 15 MPa of bonding pressure for 5 minutes in a nitrogen atmosphere. Under accelerated experiments, we monitored the degradation of the sintered Cu bond in the samples through C-mode scanning acoustic microscope (C-SAM) images. To quantify the defect percentage in C-SAM images, we investigated image denoising techniques to exclude the pattern prints. Finally, we cross-sectioned a sample and obtained scanning electron microscope images, which revealed adhesive fracture as the dominant failure mechanism.
No takes yet. Share an insight, caveat, or question.
Paret et al. (2024) studied this question.